Versions:
- BIOS: 01.08.0003
- ME: 02.01.07.112
- BMC: 1.17.4151
- frusdr: 1.08
BIOS Changes:
- Added C0 microcode version 0x405 for intel Xeon processor E5-2600/2400 v2.
- Quiet Boot option doesn't work sometimes.
- BIOS can't automatically detect the boot files on the local HDD in EFI optimized boot mode.
- Utility such as DMIDECODE and SYSCFG utility can't get SMBIOS information under UEFI RHEL 6.2.
- Device on PCIe slot 4 cannot be recognized on Intel server Board S2400SC.
- NIC1 Port2 PXE still shows as a boot option even when disabled in setup on on Intel Server board S1400SP.
- Some add-on graphics card have compatibility issues with Microsoft Windows 7.
- The length of BMC user password doesn't meet the specification.
- S3 resume will hang sometimes.
- NM Power reading is incorrect on Intel Server Boards S2400SC and S2400EP.
- Issue on Intel Workstation Board W2600CR2 w/ Nvidia Quadro K5000 video adapter.
- Update USB Stack to fix several USB issues.
- HDD Driver Fault LED can't be set on Intel Server Board S2400LP.
- Update BIOS to higher UEFI version causes some failures with the flash utility.
- System will hang after setting NIC1 Port1 to Disabled and then performing a reboot on Intel Server Board S4600LH.
- Correct SMBIOS Type 8 E-USB Connector Port Type on Intel Server Board S4600LH.
- Add Fast Video feature on multiple platforms.
- Update Onboard LAN Oprom incl. 1G/10G PXE, 10G FCoE, iSCSI.
- Update ACM version.
- Add support for the Intel Xeon processor E5-2600 v2 series - bootable only.
- Add a warning message for the first boot if an Intel Xeon processor E5-2600 v2 production processor is inserted.
- Add NTB support for Intel Server Board S2600CO.
- Serial Over Lan function works if Console Redirection is either disabled or enabled.
- Update ME version.
- Does not display add-in card option rom in Quite Boot Mode.
- Update help strings for setup item "Memory SPD Override".
- Add Intel Server Board S4600LH support for production.
- Update Board Pre-link Initial Values, VGA selection routine to cover up to four sockets on Intel Server Board S4600LH.
ME Changes:
- ME may fail to perform reset initiated with IPMI command (02h Cold Reset or DFh Force ME Recovery) - observed after few hundreds of successful resets.
- CPU Memory Throttling Status sensor gets latched in "upper non recoverable" state following Memory Throttling event after G3.
BMC Changes:
- S4600LH: Updated to FRUSDR 19 package
- S2600JF: Updated to FRUSDR 1.10 package
- S2400SC: Updated to FRUSDR 1.08 package
- S2400EP: Updated to FRUSDR 1.01 package
- S1400FP: Updated to FRUSDR 1.01 package
- S2600WP: Updated to FRUSDR 1.07 package
- S2400BB: Updated to FRUSDR 1.02 package
- S1600JP: Updated to FRUSDR 1.00 package
- Fixed typo in uboot code for S1400FP
- VFP power led always solid green while system into S1 state.
- FW versions retrieved by IHC are incorrect.
- PSU Config Error dessert event not in SEL after removal of incorrect power supply.
- Fix a DIMM Thrm Mgn error in SEL while load BIOS EPSD default
- Embedded Web Server SEL logs, added "OS Event" as the sensor name for events generated by 0x0041, to resolve incorrect sensor name & type of SEL after Windows 2008 R2 64bit graceful shutdown
- Remove the option of selecting IPv6 address from lcp.
- Some special characters show incorrectly on the LCP
- The last BIOS POST code on the LCD panel doesn't match with the boards POST CODE LED.
- Failed to test PEF Bit for Get PEF Capabilities.
- LCP displays "No BIOS POST C" when enter into LPC under VIEW menu.
- Connecting LCP to faulty system (system which keeps logging events) then LCP is unusable.
- Multiple KVM socket error and media redirection errors
- Embedded Web Server - JViewer "Error opening video socket" (Console Redirection Fails)
- Web Console Remote Session check.
- BMC FW versions displayed by LCP are incorrect
- SOL session started in SMASH session times out after 5 minutes
- SSH SMASH session does not allow settings1/timeout value greater than 600 seconds.
- LCP Configuration LAN Subnet Mask shortened name incorrect.
- VBAT voltage is low from BMC sensor reporting.
- PEF Postpone timer test failing
- S4600LH: LCP displays incorrect Server Name
- LCP: Active event is displayed incorrectly
- LCP custom string not replacing the banner
- Embedded Web console not displaying sensor values for sensors from another controller
- IPv6 is not supported on LCP, but the "Conf" screen showed an option to configure IPv6 address.
- Update PSSF162202A firmware
- Bootloader changes
- CRC 16 changes to fix firmware update failure issue.
- Fix for READ_EIN and READ_PIN calculation
- Fix includes Embedded Web Server reporting 0 W, double Power value workaround for ME issue.
- Add auto detection, sensor, and Fan Speed Control support for Intel Xeon Phi Coprocessor adapters
- Added additional product ID for Intel Xeon Phi Coprocessor
- S4600LH: Change maximum link speed of RMM4 Dedicated NIC to 100Mbps
- Fix wrong slot number mapping for S2600GZ/S2600GL. Slot numbers were reversed.
- 1200 W 02 F PSU FW file name was specified in hex instead of decimal.
- Correcting the same to maintain consistency and for correct release notes generation.
- S4600LH: LAN sku, doesn't have Power button.
- BMC shouldn't support "stayoff" option in power restore policy.
- Restore policy should be POWERON by default.
- S2600JF and S2600WP: IO Mod Presence shows not present when SAS Module is present.
- Power Unit Redundancy sensor did not behave as expected.
- The Power Unit Redundancy sensor was not getting rearmed when AC/DC Input power was removed and then restored.
- When interrupting input power from one of the redundant power supplies, the Status LED will blink green.
- Restoring power to the power supply causes the Status LED to return to solid green and there is a SEL entry for Redundancy regained.
- Scale CFM sensor reading by B value in SDR.
- Platforms are using different scaling factors in the SDR for the system CFM sensor. This change reads the scaling factor from the SDR and adjusts the raw sensor reading accordingly.
- When a Power Supply was inserted, the PS Redundancy sensor was not getting rearmed.
- The PS Redundancy sensor is rearmed when a PS is inserted and full redundancy is regained.
- When redundancy is regained, the LED should stop blinking and turn solid green.
- There should also be a Redundancy Regained SEL event logged.
- Added: Disable POST codes LED output after system has completed POST
FRUSDR Changes:
- S2600CP.sdr: Modify sensor number 02 "Pwr Unit Redund" Remove De-assertion event from FF00 change to 0000.
- S2600CP.sdr: Modify sensor number 70/71 "P1 Status"/"P2 Status" Assertion Event Mask/Deassertion Event Mask/Reading Mask to 8200.
- S2600CP.sdr: Modify sensor number 90/91 P1 VRD Hot/P2 VRD Hot Sensor Capabilities to 40.
- S2600CP.sdr: Modify sensor number 94~97 P1 MEM01 VRD Hot/P1 MEM23 VRD Hot/P2 MEM01 VRD Hot/P2 MEM23 VRD Hot Sensor Capabilities to 40.
- S2600CP.sdr: Modify sensor number F0~FE,60~68 HDD 0 Status to HDD 23 Status Assertion Event Mask/Deassertion Event Mask/Reading Mask to 8300.
- S2600CP.sdr: Modify sensor number 34/35 'P1 MTT"/"P2 MTT" M = 0x05, B=0x00, Rexp/Bexp = 0xF0.
- Update FRUSDR utility Version 11.0 Build 14.

Intel P4000CP Server System Firmware 01.08.0003 driver tags:

0003, lcp, board, P4000CP Server System, sensor, intel, frusdr, server, P4000CP. You may download directly. Please write the reviews of the Intel P4000CP Server System Firmware 01.08.0003.

Similar Intel P4000CP Server System Firmware 01.08.0003 software drivers: